Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstracts
Case Report
Case Report, Infectious Diseases
Case Report, Nephrology
Case Series
Case Series, Nephrology
Commentary
Editorial Board
EDITORIAL BOARD 2026-2-2
Original Article, Urology and Renal Surgery
Original Research Article
Original Research Article, Endocrinology and Metabolism
Original Research Article, Nephrology
Perspectives and Opinions
Perspectives and Opinions, Health Education
Prespective
Review Article
Review Article, Dialysis and Transplantation
Review Article, Nephrology
Review Article, Pediatric Nephrology
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstracts
Case Report
Case Report, Infectious Diseases
Case Report, Nephrology
Case Series
Case Series, Nephrology
Commentary
Editorial Board
EDITORIAL BOARD 2026-2-2
Original Article, Urology and Renal Surgery
Original Research Article
Original Research Article, Endocrinology and Metabolism
Original Research Article, Nephrology
Perspectives and Opinions
Perspectives and Opinions, Health Education
Prespective
Review Article
Review Article, Dialysis and Transplantation
Review Article, Nephrology
Review Article, Pediatric Nephrology
View/Download PDF
Review Article
2 (
4
); 161-165
doi:
10.25259/WARM_24_2026

Translate:

Vascular access surveillance in hemodialysis patients: Are we doing enough?

Author affiliations
Department of Medicine, Lagos State University Teaching Hospital, Lagos, Nigeria,
Department of Nephrology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India.
Article History
Corresponding author(s)
Author image
Corresponding author: Sotomiwa Olukunle Sotubo, Department of Medicine, Lagos State University Teaching Hospital, Lagos, Nigeria. tomiwasotubo@gmail.com
Article tools · PDF & citations

Abstract

Vascular access serves as the crucial lifeline for patients undergoing maintenance hemodialysis. Despite technological and clinical advancements, access-related complications – predominantly stenosis and secondary thrombosis – remain one of the leading causes of patient morbidity, frequent hospitalizations, and escalating healthcare expenditures in end-stage renal disease. Effective access surveillance strategies aim to detect subclinical vascular dysfunction early, enabling timely percutaneous or surgical interventions before catastrophic failure occurs. This review evaluates contemporary surveillance modalities, critically analyses systemic gaps in current clinical practice, and explores future paradigms – including artificial intelligence, point-of-care ultrasound, and standardized policy frameworks – to optimize vascular access longevity.

Keywords

  • Access surveillance
  • Arteriovenous fistula
  • Hemodialysis
  • Stenosis
  • Vascular access
Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

How to cite this article: Sotubo SO, Sharma S, Amisu M, Adekoya A, Awobusuyi O. Vascular access surveillance in hemodialysis patients: Are we doing enough? World Adv Renal Med. 2026;2:161-5. doi: 10.25259/WARM_24_2026

INTRODUCTION

Achieving effective hemodialysis requires a durable vascular access, whether autogenous arteriovenous fistula (AVF) or synthetic arteriovenous graft (AVG). However, access failure represents a major limitation in end-stage renal disease management.[1] Neointimal proliferation near the anastomosis or venous junction causes gradual stenosis, disrupting fluid dynamics and lowering access flow rates (Qa), which ultimately precipitates complete vascular thrombosis.[2]

Rather than waiting to treat acute thrombosis as it occurs, current medical practice emphasizes early intervention through two complementary strategies: Monitoring – the routine physical checks and clinical evaluations performed during each dialysis session – and surveillance – the scheduled diagnostic testing that uses specialized tools to track blood flow rates, intra-access pressures, and structural patency.[3]

Despite recent guideline revision by the Kidney Disease Outcomes Quality Initiative (KDOQI), clinicians continue to question whether standardized routine surveillance reliably improves patient outcomes in a cost-effective manner.[4,5]

SECTION 1: CURRENT SURVEILLANCE METHODS

Physical examination and clinical monitoring

Physical examination remains the most accessible, low-cost diagnostic tool available to nephrologists, vascular surgeons, and dialysis nursing staff.[6]

  • Inspection: Assessing for aneurysm formation, skin breakdown, collateral vein recruitment, or arm edema

  • Palpation: Evaluating the thrill along the vessel track and assessing pulse character (hyperpulsatile vs. soft). The arm elevation test is used to identify outflow stenosis (failure of the fistula to collapse when raised above heart level), while the pulse augmentation test evaluates inflow tract integrity.

The pulse augmentation test is a simple bedside physical examination technique used to evaluate the integrity of the inflow tract (the feeding artery and arterial anastomosis) of an AVF; fingers are placed over the proximal body of the fistula vein, close to the arterial anastomosis, to feel the baseline pulse and thrill. While keeping your fingers on the proximal vessel, the other hand is used firmly to compress (occlude) the body of the fistula several centimeters downstream (distal to your palpating fingers, toward the outflow).

Observe and feel the change in the character of the pulse in the vessel segment between the arterial anastomosis and the point of manual occlusion. There is said to be a positive augmentation if the pulse behind the occlusion point becomes markedly hyperpulsatile, bounding, and strong. This confirms that arterial inflow into the fistula is robust and unobstructed. Failed Augmentation means that the pulse does not increase in strength or remains weak and soft despite complete downstream occlusion. This suggests an inflow stenosis (e.g., feeding artery stenosis or a juxta-anastomotic lesion).[7]

The pulse augmentation test is typically paired with the arm elevation test during routine physical surveillance. The pulse augmentation test identifies inflow (arterial side) issues while the arm elevation test identifies outflow (venous side) stenosis when the vein fails to collapse upon elevating the arm above the level of the heart.[8]

  • Auscultation: Detecting high-pitched, continuous bruits indicative of localized luminal narrowing.

Limitations

Clinical physical assessment relies heavily on clinician expertise, making its diagnostic consistency both subjective and variable. Consequently, early-stage or deep intrathoracic lesions frequently escape detection during physical checks until access flow becomes severely impaired. It is also not reliable when used to assess AVG.[8]

Imaging-based techniques

  • Duplex ultrasound (DUS): Non-invasive, real-time assessment of hemodynamic and vascular anatomy. DUS quantifies luminal diameter, peak systolic velocity (PSV) ratios, and absolute access flow volume (Qa). A PSV ratio >2.0 or 3.0 strongly correlates with a stenosis >50%.[9,10]

  • Digital subtraction angiography (DSA): Long considered the benchmark for anatomical assessment, DSA delivers precise diagnostic imaging alongside the capacity for immediate endovascular treatment through percutaneous transluminal angioplasty. Nevertheless, high operational costs, ionizing radiation exposure, and potential adverse reactions to hyperosmolar contrast media prevent its adoption as a routine screening method.[11]

Pressure and flow monitoring

  • Access flow (Qa) measurement: A persistent monthly drop in Qa exceeding 25%, or absolute flow values falling under 500–600 mL/min for AVFs (600–800 mL/min for AVGs), acts as a key physiological warning sign warranting prompt radiological evaluation.[5,12,13]

  • Venous static pressure ratio: Quantifies internal static access pressure against systemic mean arterial pressure. Elevated baseline values (>0.50 for AVFs and >0.35–0.40 for AVGs) serve as a diagnostic marker for downstream venous outflow obstruction.[14]

  • Recirculation testing: Detection of cardiopulmonary or local access recirculation (through urea concentrations or optical sensors) typically reflects advanced flow impairment (Qa falling below dialyzer blood pump speed).[15,16]

SECTION 2: GAPS IN SURVEILLANCE PRACTICES

Heterogeneity in implementation

Variability among global practice guidelines creates operational ambiguity for outpatient dialysis clinics. Unlike historical recommendations supporting monthly access flow monitoring, the updated 2019 KDOQI framework prioritizes physical examination, reserving routine surveillance for cases with overt clinical red flags such as difficult cannulation, persistent post-dialysis bleeding, or inadequate clearance. Consequently, institutional protocols remain highly fragmented, leading to disparities in care delivery.[3]

Delayed interventions and systemic barriers

Surveillance data is only as effective as the secondary response system it triggers.

  • Communication bottlenecks: Protracted delays between detecting abnormal surveillance metrics – such as a falling access flow (Qa) – and initiating interventional referrals often result in acute vascular thrombosis while patients remain on waiting lists.[1]

  • Multidisciplinary disconnect: Fragmented communication between nephrologists, vascular access nurses, interventional radiologists, and transplant/vascular surgeons reduces the agility needed for preemptive angioplasty.[17]

Underutilization of advanced technologies

Despite the proven utility of real-time inline flow sensors and point-of-care ultrasound (POCUS), integration into daily dialysis unit workflows remains sparse.[18] Key barriers include:

  • High initial equipment capital costs and ongoing software licensing

  • Insufficient time allotted per nursing shift for specialized measurements

  • Lack of standardized billing and reimbursement models for routine bedside ultrasound surveillance by nephrologists [Figure 1].

Current surveillance gaps.
Figure 1: Current surveillance gaps.

SECTION 3: IMPROVING SURVEILLANCE STRATEGIES

Integration of artificial intelligence (AI) and machine learning

AI holds potential to shift surveillance from intermittent snapshot measurements to continuous predictive monitoring.[19]

  • Predictive analytics: Preliminary models utilizing machine learning algorithms (e.g., random forests, neural networks) are being investigated for their capacity to analyze multi-variable inputs – such as historical dynamic venous pressures, continuous blood pump speeds, arterial line pressures, blood urea nitrogen clearance rates, and systemic blood pressure trends – toward potential generation of a daily “thrombosis risk score.”[20]

  • AI-enhanced bedside ultrasound: Emerging automated DUS software uses computer-vision algorithms to delineate lumen borders, auto-calculate PSV ratios, and estimate Qa, though further clinical trials are required to determine whether these tools can function reliably independently of advanced operator expertise [Figure 2].[21-24]

Integrated artificial intelligence surveillance paradigm.
Figure 2: Integrated artificial intelligence surveillance paradigm.

Standardized education and training

  • Staff competency: Establishing mandatory, structured training modules for hemodialysis nurses and clinical staff focused on advanced physical examination (arm elevation, pulse augmentation), and basic POCUS cannulation and evaluation.

  • Patient self-monitoring: Empowering patients through structured education regarding daily thrill palpation, recognition of localized warmth/erythema, and early reporting of prolonged post-dialysis bleeding.

Policy and protocol harmonization

  • National and international consensus: Professional societies must reconcile divergent recommendations into unified, actionable clinical pathways that define exact Qa drop thresholds requiring referral

  • Individualized surveillance risk stratification: Transitioning from “one-size-fits-all” monthly screening to stratified risk schedules [Table 1].

Table 1: Surveillance risk stratification.
Access type/Risk tier Clinical profile Recommended surveillance frequency
Low-risk native AVF Mature, stable Q a >800 mL/min, no prior interventions Monthly physical exam; quarterly Q a testing
High-risk native AVF Juxta-anastomotic stenosis history, recent PTA Bi-weekly physical exam; monthly Q a+POCUS
Synthetic AVG Synthetic graft material, high intrinsic thrombosis risk Monthly Q a measurement+ baseline DUS

PTA: Percutaneous transluminal angioplasty, DUS: Duplex ultrasound/Doppler ultrasound, AVF: Arteriovenous fistula, AVG: Arteriovenous graft, POCUS: Point-of-care ultrasound, Qa: Vascular access flow rate.

CONCLUSION

The current management of vascular access surveillance remains overly reactive, often responding only after severe stenosis presents as cannula failure or acute thrombosis. Optimizing vascular access longevity requires a paradigm shift toward a multimodal, proactive framework. Combining structured physical examinations, accessible bedside ultrasound, automated intra-dialytic pressure tracking, and AI-driven predictive algorithms will allow clinical teams to identify subclinical lesions earlier, preserve vascular anatomy, and ultimately improve outcomes for maintenance hemodialysis patients.

Authors’ contributions:

SOS: Conceptualization, literature search, preparation of original draft; SS: Conceptualization, structure of literature; MA: Review and edit; AA: Review and edit; OA: Supervisory.

Ethical approval:

Institutional Review Board approval is not required.

Declaration of patient consent:

Patient’s consent is not required as there are no patients in this study.

Conflicts of interest:

There are no conflicts of interest.

Use of artificial intelligence (AI)-assisted technology for manuscript preparation:

The authors confirm that there was use of artificial intelligence (AI)-assisted technology to rectify grammatical errors and refine presentation.

Financial support and sponsorship: Nil.

References

  1. , , , , . Hemodialysis vascular access flow surveillance: Current evidence and future directions. J Chin Med Assoc. 2025;88:815-24.
    [CrossRef] [PubMed] [Google Scholar]
  2. , , , , , , et al. Venous cannulation site stenosis and risk of recurrence: A new hypothesis. Cureus. 2025;17:e92950.
    [CrossRef] [Google Scholar]
  3. , , , , , , et al. KDOQI clinical practice guideline for vascular access: 2019 update. Am J Kidney Dis. 2020;75:S1-64.
    [CrossRef] [PubMed] [Google Scholar]
  4. , . KDOQI 2019 vascular access guidelines: What is new? Adv Chron Kidney Dis. 2020;27:3-8.
    [CrossRef] [PubMed] [Google Scholar]
  5. , , . Vascular access surveillance: An ongoing controversy. Kidney Int. 2012;81(2):132-42.
    [CrossRef] [PubMed] [Google Scholar]
  6. , . Listening to the lifeline: Harnessing sound to monitor dialysis vascular access. Kidney360. 2025;6:1647-8.
    [CrossRef] [PubMed] [Google Scholar]
  7. , , , , . Measuring the palpable pulsatility length as a physical examination test in defining the severity of inflow stenosis for hemodialysis fistulas. BMC Nephrol. 2019;20:356.
    [CrossRef] [PubMed] [Google Scholar]
  8. , , . Clinical aspects of dialysis interventions: Physical and sonographic findings. Semin Intervent Radiol. 2022;39:9-13.
    [CrossRef] [PubMed] [Google Scholar]
  9. , , . Duplex ultrasound compared with digital subtraction angiography in diagnosing significant stenosis of vascular access. Int Urol Nephrol. 2025;57:3889-95.
    [CrossRef] [PubMed] [Google Scholar]
  10. , , . Developing Duplex ultrasound criteria for diagnosis of arteriovenous fistula stenosis. Ann Vasc Surg. 2017;38:99-104.
    [CrossRef] [PubMed] [Google Scholar]
  11. , , , , , , et al. A pilot study on adjunctive use of parametric colour-coded digital subtraction angiography in endovascular interventions of haemodialysis access. BMC Med Imaging. 2018;18:28.
    [CrossRef] [PubMed] [Google Scholar]
  12. , , , , . Weight-based assessment of access flow threshold to predict arteriovenous fistula functional patency. Kidney Int Rep. 2022;7:507-15.
    [CrossRef] [PubMed] [Google Scholar]
  13. , , , , , . Hemodialysis access blood flow rates can be measured by a differential conductivity technique and are predictive of access clotting. Am J Kidney Dis. 1997;30:475-82.
    [CrossRef] [PubMed] [Google Scholar]
  14. , , . Value of static venous pressure for predicting arteriovenous graft thrombosis. Kidney Int. 2002;61:1899-904.
    [CrossRef] [PubMed] [Google Scholar]
  15. , , , . Prevalence of recirculation and related factors among hemodialysis patients in Golestan Province, Iran Keywords. J Res Dev Nurs Midwifery. 2024;20:4-7.
    [CrossRef] [Google Scholar]
  16. , . Recirculation, urea disequilibrium, and dialysis efficiency: Peripheral arteriovenous versus central venovenous vascular access. Am J Kidney Dis. 1997;29:479-89.
    [CrossRef] [PubMed] [Google Scholar]
  17. . Role of interventional nephrology in the multidisciplinary approach to hemodialysis vascular access care. Kidney Res Clin Pract. 2015;34:125-31.
    [CrossRef] [PubMed] [Google Scholar]
  18. , , , , , , et al. Development and evaluation of a kidney point-of-care ultrasound (POCUS) training program for nephrology fellows: A quality improvement study. Canad J Kidney Health Dis. 2025;12:20543581251378793.
    [CrossRef] [PubMed] [Google Scholar]
  19. . AI-driven predictive analytics in monitoring and evaluation: Opportunities and ethical dilemmas. Stud Econ Bus Relat. 2025;6:52-62.
    [CrossRef] [Google Scholar]
  20. , , . Comparative Analysis of Machine Learning Algorithms for Blood Pressure Prediction United States: IEEE; .
    [Google Scholar]
  21. . Artificial intelligence in diagnostic ultrasonography. Diagn Interv Radiol. 2023;29:40-5.
    [CrossRef] [PubMed] [Google Scholar]
  22. , , , , , , et al. Adding access blood flow surveillance to clinical monitoring reduces thrombosis rates and costs, and improves fistula patency in the short term: A controlled cohort study. Nephrol Dial Transplant. 2008;23:3578-84.
    [CrossRef] [PubMed] [Google Scholar]
  23. , , , . Point of care ultrasound of the hemodialysis vascular access. POCUS J. 2022;7:105-9.
    [CrossRef] [PubMed] [Google Scholar]
  24. , , , , , , et al. Artificial intelligence and machine learning in predicting intradialytic hypotension in hemodialysis patients: A systematic review. Cureus. 2024;16:e65334.
    [CrossRef] [Google Scholar]
Show Sections