Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstracts
Case Report
Case Report, Infectious Diseases
Case Report, Nephrology
Case Series
Case Series, Nephrology
Commentary
Editorial Board
EDITORIAL BOARD 2026-2-2
Original Article, Urology and Renal Surgery
Original Research Article
Original Research Article, Endocrinology and Metabolism
Original Research Article, Nephrology
Perspectives and Opinions
Perspectives and Opinions, Health Education
Prespective
Review Article
Review Article, Dialysis and Transplantation
Review Article, Nephrology
Review Article, Pediatric Nephrology
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstracts
Case Report
Case Report, Infectious Diseases
Case Report, Nephrology
Case Series
Case Series, Nephrology
Commentary
Editorial Board
EDITORIAL BOARD 2026-2-2
Original Article, Urology and Renal Surgery
Original Research Article
Original Research Article, Endocrinology and Metabolism
Original Research Article, Nephrology
Perspectives and Opinions
Perspectives and Opinions, Health Education
Prespective
Review Article
Review Article, Dialysis and Transplantation
Review Article, Nephrology
Review Article, Pediatric Nephrology
View/Download PDF
Original Research Article
2 (
4
); 166-172
doi:
10.25259/WARM_20_2026

Translate:

Outcome of percutaneous peritoneal dialysis catheter insertion

Author affiliations
Department of Nephrology, Nizwa Hospital, Ministry of Health, Nizwa, Oman,
Department of Nephrology, AlAzhar University, Cairo, Egypt,
Department of Anesthesiology, Nizwa Hospital, Ministry of Health, Nizwa, Oman.
Department of Radiology, Nizwa Hospital, Ministry of Health, Nizwa, Oman.
Article History
Corresponding author(s)
Author image
Corresponding author: Khalfan Salim AlShaaili, Department of Nephrology, Nizwa Hospital, Ministry of Health, Nizwa, Oman. khalfanalshaaili@gmail.com
Article tools · PDF & citations

Abstract

Objectives:

Peritoneal dialysis (PD) is an effective home-based renal replacement therapy for patients with end-stage renal disease (ESRD). However, timely and safe catheter insertion remains a barrier to its widespread adoption. Percutaneous PD catheter insertion by nephrologists has emerged as a safe alternative to surgical techniques. This study aimed to evaluate the outcomes and safety of nephrologist-performed percutaneous PD catheter insertion using a combined ultrasound and fluoroscopy-guided approach at a regional hospital in Oman.

Material and Methods:

This was a retrospective cohort study conducted at the Nephrology Department, Nizwa Hospital, Sultanate of Oman, between September 2022 and December 2025. All consecutive adult patients with ESRD who underwent percutaneous PD catheter insertion by the trained nephrology team were included. Procedures were performed under local anesthesia using ultrasound for abdominal wall assessment and fluoroscopy with contrast to confirm intraperitoneal placement. The study evaluated technical success and early procedural and post-insertion complications; 1-year catheter survival, transfer to hemodialysis, and late catheter revision were outside its scope.

Results:

A total of 79 patients (60.8% male, mean age 56.8 ± 16.6 years) underwent percutaneous PD catheter insertion. The success rate was 88.6% (70/79; 95% confidence interval: 79.5–94.2%). No bowel perforation occurred. The most common causes of failure were preperitoneal placement (33.3%) and surgical adhesions (33.3%). Early leakage was the most frequent mechanical complication (7.6%). Prophylactic antibiotics were administered in 100% of patients. Early peritonitis occurred in 1 patient (1.3%) and exit site infections in 3 patients (3.8%). Pseudomonas aeruginosa was the most common organism (2 cases). Failure of insertion decreased from 15.0% in the first 40 insertions to 7.7% in the last 39 insertions. Urgent-start PD (53.2% of patients) was associated with higher early leakage (11.9% vs. 2.7%).

Conclusion:

Percutaneous PD catheter insertion by nephrologists using image guidance is safe and effective, with improving outcomes over time. Urgent-start PD is feasible but requires caution due to higher leakage risk.

Keywords

  • Catheter-related complications
  • Exit site infection
  • Percutaneous insertion
  • Peritoneal dialysis
  • Peritonitis
Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

How to cite this article: AlShaaili KS, El Sayed HM, Alsaeghi SS, Alsulaimi AA, Al-Rawahi KS, Al-Busaidi SA. Outcome of percutaneous peritoneal dialysis catheter insertion. World Adv Renal Med. 2026;2:166-72. doi: 10.25259/WARM_20_2026

INTRODUCTION

Peritoneal dialysis (PD) is a well-established home-based renal replacement therapy for patients with end-stage renal disease (ESRD), offering several advantages over hemodialysis, including better preservation of residual renal function, hemodynamic stability, and improved quality of life.[1,2] The COVID-19 pandemic further highlighted the value of PD as a safe, resource-efficient modality that reduced patient congestion in dialysis centers and helped overcome shortages of dialysis solutions and continuous renal replacement therapy machines during crisis periods.[3]

A critical factor limiting the widespread adoption of PD is the timely and safe insertion of a well-functioning PD catheter. Conventionally, catheters have been placed by surgeons using open or laparoscopic techniques, which require operating theatre availability, anesthesia support, and often lead to scheduling delays.[4,5] In recent years, percutaneous catheter insertion by nephrologists has emerged as a safe and effective alternative, with outcomes comparable to surgical placement, shorter waiting times, reduced hospital stay, and avoidance of general anaesthesia.[6,7] Studies have demonstrated that image-guided percutaneous techniques are associated with lower rates of infectious and mechanical complications compared to direct visualization techniques.[8]

At Nizwa Hospital, we initiated a program to train nephrologists in percutaneous PD catheter insertion using a combined ultrasound and fluoroscopy-guided approach to maximize patient safety. We also aimed to establish an emergency PD service to reduce the need for urgent hemodialysis through central catheters. This study was conducted to assess the safety, feasibility, and clinical outcomes of this service.

MATERIAL AND METHODS

This was a retrospective cohort study conducted at the Nephrology Department, Nizwa Hospital, Ministry of Health, Oman. The study included all consecutive patients who underwent percutaneous PD catheter insertion by trained members of the nephrology team between September 2022 and December 2025.

The study was done after approval from the Institutional Ethics Committee of Nizwa Hospital (approval code: DGHS/R&S/PROPOSAL_APPROVED/2024).

Inclusion criteria

  • All adult patients (age ≥18 years) with ESRD requiring PD catheter insertion during the study

  • Patients referred for percutaneous PD catheter placement regardless of sex, comorbidity, or body habitus.

Exclusion criteria

  • Previous extensive abdominal surgery with suspected dense intraperitoneal adhesions

  • Bleeding diathesis or uncorrected coagulopathy

  • Active abdominal wall infection at the proposed insertion site

  • Patients who declined to provide informed consent for the procedure.

PD catheter insertion technique

All procedures were performed by trained members of the Nizwa Hospital nephrology team under local anesthesia, with sedation if needed. The procedures were not all performed by a single operator. Pre-procedurally, ultrasound was used to scan the abdominal wall to identify the inferior epigastric vessels and assess for any interposed abdominal organs. Under aseptic conditions, a paramedian entry site was selected. Using the Seldinger technique, a guidewire was introduced into the peritoneal cavity under fluoroscopic guidance after contrast injection to confirm intraperitoneal position and exclude bowel or organ perforation. A double-cuffed coiled Tenckhoff catheter was then advanced into the pelvic position. Catheter function was tested intraoperatively by instilling and draining 500 mL of warmed dialysis fluid. The catheter was tunneled subcutaneously, and the exit site was directed laterally or downward. Prophylactic intravenous antibiotics (cefazolin or vancomycin) were administered before the procedure according to local protocol.

Post-procedure care and PD initiation

After insertion, the catheter was locked with heparinized saline. PD was initiated when clinically indicated, with a planned break-in period of 7–14 days. Urgent-start PD was operationally defined as PD initiation within 14 days (≤14 days) of catheter insertion, consistent with the widely used definition of starting PD before completion of the conventional 2-week break-in period.[4] Some programs use narrower thresholds, such as <72 h or <7 days; however, the 14-day cutoff was selected to evaluate all starts occurring before the guideline-recommended 2-week break-in period. In urgent-start cases, exchanges were performed in the supine position with low dwell volumes. All patients received structured PD training before home discharge.

Outcomes

The primary outcomes were successful catheter insertion and the occurrence of early mechanical or infectious complications. Secondary outcomes included time to first PD initiation. This study was designed to assess immediate technical and early post-insertion outcomes and did not evaluate 1-year catheter survival, transfer to hemodialysis, or late catheter revision. Definitions were adapted from the International Society for PD (ISPD) guidelines.[4,9,10]

Statistical analysis

Statistical analysis was performed using the Statistical Package for the Social Sciences version 26 (IBM Inc., Armonk, NY, USA). Continuous variables were expressed as mean ± standard deviation (SD) or median with interquartile range as appropriate. Categorical variables were presented as frequencies and percentages. Fisher’s exact test was used to compare categorical variables between groups. A two-tailed p < 0.05 was considered statistically significant.

RESULTS

Nizwa Hospital is considered to be a leading hospital in PD care in the Sultanate of Oman, receiving patients from different regions across the country.

A total of 79 patients underwent percutaneous PD catheter insertion during the study period. The cohort had a male predominance (60.8%) with a mean age of 56.8 years. The body mass index (BMI) ranged from 15.5 to 39.7 kg/m2 with a mean of 25.96 kg/m2. Hypertension (79.7%) and diabetes mellitus (68.4%) were the most common comorbidities [Table 1].

Table 1: Baseline characteristics of the studied patients (n=79).
Characteristic Mean±SD n (%)
Age (years) 56.78±16.61 –
Height (cm) 158.31±14.12 –
Weight (kg) 67.69±19.53 –
BMI (kg/m2) 25.96±5.00 –
Male – 48 (60.8)
Female – 31 (39.2)
Diabetes mellitus – 54 (68.4)
Hypertension – 63 (79.7)
Glomerulonephritis – 5 (6.3)
Days between insertion and PD initiation 16.48±14.19
Urea (mg/dL) 24.89±10.02
Creatinine (µmol/L) 700.91±316.05
eGFR (mL/min) 8.27±4.07
Hemoglobin (g/dL) 10.06±1.62
Albumin (g/L) 37.13±5.96

BMI: Body mass index, eGFR: Estimated glomerular filtration rate, PD: Peritoneal dialysis, SD: Standard deviation

Usually, PD is initiated 2–3 weeks after insertion. In our study, the mean time to PD initiation was 16.48 days (SD 14.19). Of the 79 patients, 42 patients (53.2%) started PD within 14 days or less (urgent-start group), and 37 patients (46.8%) started after more than 14 days (planned-start group). Laboratory values reflect advanced chronic kidney disease (mean estimated glomerular filtration rate 8.27 mL/min) [Table 1].

The success rate of percutaneous PD catheter insertion was 88.6% (70/79). No bowel perforation occurred in any patient, supporting the safety of the fluoroscopy-guided percutaneous technique [Table 2 and Figure 1].

Table 2: Catheter insertion outcomes.
Outcome (n=79) n % (95% CI)
Successful insertion 70 88.6% (79.5–94.2)
Failed insertion 9 11.4% (5.8–20.5)
Reason for insertion failure (n=9) n % of failures
Preperitoneal insertion 3 33.3
Surgical adhesions 3 33.3
Pain 1 11.1
Omental wrapping 1 11.1
High BMI 1 11.1

BMI 1 11.1 BMI: Body mass index, CI: Confidence interval

Catheter insertion outcomes and reasons for failure. BMI: Body mass index.
Figure 1: Catheter insertion outcomes and reasons for failure. BMI: Body mass index.

Pre-peritoneal insertion and surgical adhesions were the most common causes of failure, each accounting for 33.3% of failed insertions. Technical factors (preperitoneal placement, omental wrapping) and patient-related factors (adhesions, high BMI, pain) both contributed to unsuccessful procedures [Table 2]. Pain and procedural discomfort were managed using local anesthesia and intravenous paracetamol for analgesia, with midazolam administered for sedation when required. Preperitoneal insertion was managed by using a longer introducer needle (Veress needle −12 cm) and fluoroscopy with contrast. Surgical adhesions were referred to the surgery team.

Early leakage was the most frequent mechanical complication (6 patients, 7.6%), followed by Preperitoneal placement (3 patients, 3.8%) and catheter migration (2 patients, 2.5%). Hemorrhage and no outflow occurred in 1 case each. No bowel perforation was observed. Prophylactic antibiotics were administered in 100% of patients [Table 3 and Figure 2].

Mechanical and infectious complications.
Figure 2: Mechanical and infectious complications.
Table 3: Mechanical and infectious complications.
Complication n % (95% CI)
Mechanical complications
  Early leakage 6 7.6 (3.1–15.9)
  Preperitoneal placement 3 3.8 (1.0–10.8)
  Migration 2 2.5 (0.4–9.0)
  Hemorrhage 1 1.3 (0.1–7.2)
  No outflow 1 1.3 (0.1–7.2)
  Bowel perforation 0 0 (0–4.6)
Infectious complications
  Prophylactic antibiotics given 79 100 (95.4–100)
  Peritonitis 1 1.3 (0.1–7.2)
  Exit site infection 3 3.8 (1.0–10.8)

CI: Confidence interval

Early culture-negative peritonitis occurred in only 1 patient (1.3%), who was treated with intraperitoneal vancomycin plus prophylactic fluconazole and was completely cured, while exit site infections occurred in 3 patients (3.8%). Among patients with documented exit site infections, Pseudomonas aeruginosa was the most common organism (2 cases), both treated with ciprofloxacin. One case of Acinetobacter infection was treated with amoxicillin– clavulanate (co-amoxiclav) [Table 4].

Table 4: Identified organisms and antibiotic treatment.
Organism n % Antibiotic used
Pseudomonas aeruginosa 2 66.7 Ciprofloxacin
Acinetobacter 1 33.3 amoxicillin–clavulanate (co-amoxiclav)

To evaluate the learning curve of nephrologist-performed percutaneous PD catheter insertion, we compared the first 40 insertions with the last 39 insertions. Failure of insertion decreased from 15.0% in the first 40 insertions to 7.7% in the last 39 insertions. Preperitoneal placement occurred only in the early experience (3 cases, 7.5%). However, early leakage and exit site infections appeared to be slightly more frequent in the later experience [Table 5].

Table 5: Comparison of outcomes between first 40 and last 39 insertions.
Complication First 40 insertions (%) Last 39 insertions (%) p-value
Failure of insertion 6 (15.0) 3 (7.7) 0.481
Hemorrhage 1 (2.5) 0 (0) 1.000
No outflow 0 (0) 1 (2.6) 1.000
Preperitoneal placement 3 (7.5) 0 (0) 0.241
Migration 0 (0) 2 (5.1) 0.241
Early leakage 2 (5.0) 4 (10.3) 0.432
Peritonitis 1 (2.5) 0 (0) 1.000
Exit site infection 1 (2.5) 2 (5.1) 1.000

p < 0.05 was considered statistically significant.

Early leakage was numerically more common in the urgent- start group (11.9%) than in the planned-start group (2.7%), although the difference was not statistically significant (p = 0.206). Other complications, including failure of insertion, preperitoneal placement, and exit site infections, were comparable between the two groups [Table 6].

Table 6: Comparison of outcomes between urgent-start (≤14 days) and planned-start (>14 days) PD.
Complication Urgent-start
(n=42) (%)
Planned-start
(n=37) (%)
p-value
Failure of insertion 4 (9.5) 5 (13.5) 0.727
Hemorrhage 1 (2.4) 0 (0) 1.000
No outflow 0 (0) 1 (2.7) 1.000
Preperitoneal placement 1 (2.4) 2 (5.4) 1.000
Migration 0 (0) 2 (5.4) 0.216
Early leakage 5 (11.9) 1 (2.7) 0.206
Peritonitis 1 (2.4) 0 (0) 1.000
Exit site infection 2 (4.8) 1 (2.7) 1.000

PD: Peritoneal dialysis. p < 0.05 was considered statistically significant.

DISCUSSION

This study evaluated the outcomes of nephrology-team-performed percutaneous PD catheter insertion using a combined ultrasound and fluoroscopy-guided technique at a regional hospital in Oman. Our findings demonstrate that this approach is safe, feasible, and associated with acceptable success and complication rates during program implementation.

The overall success rate of percutaneous PD catheter insertion in our study was 88.6%. This is comparable to previously published series. Medani et al.[6] reported technical success rates of 89.5% for percutaneous insertion and 96.9% for surgical insertion, with no significant difference in primary non-function rates between the two techniques. Similarly, Islam et al.[7] found no significant difference in catheter survival or major complications between percutaneous and laparoscopic approaches. Our success rate is also consistent with the study by Li et al.,[8] which demonstrated that image- guided percutaneous catheterization significantly reduces mechanical complications compared with direct visualization techniques.

Importantly, no bowel perforation occurred in any of our 79 patients. This is a critical safety endpoint, as bowel injury remains a theoretical concern with percutaneous “blind” techniques. Our use of pre-procedural ultrasound to identify abdominal wall anatomy and intra-procedural fluoroscopy with contrast to confirm intraperitoneal guidewire placement likely contributed to this excellent safety record. Similar findings have been reported by others who adopted image- guided protocols.[8]

Early leakage was the most frequent mechanical complication in our series (7.6%), followed by Preperitoneal placement (3.8%) and catheter migration (2.5%). Our early leakage rate is comparable to the 5–13% reported in the literature for both open and laparoscopic techniques.[11,12] The incidence of pericatheter leakage varies widely across studies, ranging from 2% to 20%, depending on the break-in period, catheter type, and insertion technique.[12,13]

Importantly, we found that early leakage was significantly more common in the urgent-start group (11.9%) compared to the planned-start group (2.7%). This finding aligns with current ISPD guidelines, which recommend a break-in period of at least 2 weeks before elective PD initiation to minimize leak risk.[9] For patients requiring urgent-start PD, we adopted supine positioning and low dwell volumes, which may have mitigated but not eliminated this risk.

No catheter migration occurred in the urgent-start group, while 2 cases (5.4%) occurred in the planned-start group. This finding is reassuring, as early PD initiation did not appear to predispose to catheter displacement. The overall migration rate of 2.5% in our study compares favorably with reported rates of 2.7–15% in the literature.[13,14]

Prophylactic antibiotics were administered in 100% of our patients, reflecting strict adherence to ISPD guidelines.[9] Despite this, one patient developed early culture-negative peritonitis (1.3%), which was successfully treated with intraperitoneal vancomycin and prophylactic fluconazole. This peritonitis rate compares favorably with other published series. Medani et al.[6] reported early peritonitis rates of 5% in the percutaneous group and 7.4% in the surgical group. Agarwal et al.[15] found that percutaneous insertion was associated with a lower risk of peritonitis compared to surgical insertion (odds ratio [OR] = 0.64; 95% confidence interval: 0.47–0.76).

Exit site infections occurred in 3 patients (3.8%), with P. aeruginosa being the most common organism (2 cases), both successfully treated with oral ciprofloxacin. One case of Acinetobacter infection was treated with amoxicillin- clavulanate (co-amoxiclav). Our exit site infection rate of 3.8% is comparable to or lower than published rates for percutaneous PD catheter insertion, which range from 2.5% to 9% in contemporary series.[16,17]

We compared the first 40 insertions with the last 39 insertions to assess changes in outcomes as the nephrology- led catheter insertion program matured. Failure of insertion decreased from 15.0% in the early period to 7.7% in the later period. Preperitoneal placement occurred only in the early period (3 cases, 7.5%) and did not occur in the last 39 insertions. Because procedures were performed by members of the nephrology team rather than a single operator, these temporal findings should be interpreted as program-level improvement and cannot be attributed solely to an individual operator learning curve. Differences in operator composition between the two periods may also have contributed to the observed change.

Crabtree[18] emphasized that formal training programs for nephrologists in PD catheter insertion are essential to achieve optimal outcomes. Our experience supports the feasibility of developing a nephrology-led team to perform this technique, with acceptable outcomes during program implementation.

In our study, 53.2% of patients started PD within 14 days of insertion. This reflects the reality of late-referred ESRD patients who require immediate dialysis initiation, and in some cases, PD was a rescue therapy for ESRD patients with failed vascular access. Early leakage was more common in the urgent-start group (11.9% vs. 2.7%), although this difference did not reach statistical significance (p = 0.206), likely due to the relatively small sample size. This finding is consistent with the literature, which suggests that a shorter break-in period is associated with a higher risk of pericatheter leakage.[9,19]

Importantly, other complications including peritonitis, exit site infection, and catheter migration were not significantly different between the two groups. This suggests that urgent-start PD can be performed safely with appropriate precautions, including supine positioning, low dwell volumes, and close monitoring. Similar conclusions have been reached by others. Povlsen et al.[20] reported that unplanned urgent- start PD after catheter implantation is feasible in selected patients, with acceptable outcomes.

Our results compare favorably with published series from both developed and developing countries. In a large comparative analysis by Medani et al.,[6] the percutaneous group had a peritonitis rate of 1 episode/26 catheter-months, compared to 1 episode/19 catheter-months in the surgical group (p = 0.017). Our observed early peritonitis proportion was 1.3%. Because this study focused on early outcomes and did not collect standardized catheter-time at risk, a peritonitis incidence rate per catheter-month could not be calculated or directly compared with that study.

Islam et al.[7] comparing percutaneous Seldinger and laparoscopic techniques, found that the percutaneous approach was associated with a significantly shorter time to first PD use (13.5 vs. 21.5 days, p < 0.001) and a lower exit- site leak rate (11.1% vs. 33.3%, p = 0.039). Our mean time to PD initiation was 16.48 days, which is longer than the 13.5 days reported by Islam et al.,[7] reflecting our cautious approach with a planned break-in period of 7–14 days.

A recent meta-analysis by Li et al.,[8] which included 11 studies and 8,981 patients, demonstrated that image-guided percutaneous catheterization significantly reduced infectious complications (OR = 0.73), mechanical complications (OR = 0.64), and catheter removal rates (OR = 0.63) compared to direct visualization techniques, with no significant difference in 1-year PD catheter survival (OR = 1.33). Our findings are consistent with this meta-analysis, supporting the use of image-guided percutaneous techniques as a first-line approach for PD catheter insertion.

Limitations include the retrospective, single-center design, which may introduce selection bias. The relatively small sample size (79 patients) limited our ability to detect statistically significant differences in subgroup analyses. Procedures were performed by members of the nephrology team rather than a single operator; therefore, differences in operator composition may have influenced the comparison between the early and later periods, and the temporal improvement cannot be attributed solely to an individual learning curve. This study specifically evaluated immediate technical and early post-insertion outcomes; standardized data on 1-year catheter survival, transfer to hemodialysis, late catheter revision, and other late complications were not available and therefore could not be assessed. These long- term outcomes are the subject of a separate ongoing study. In addition, we did not perform multivariate analysis to identify independent predictors of complications, as the number of events was small. Finally, our findings may not be generalizable to centers without access to fluoroscopy or without trained nephrologists in this technique.

CONCLUSION

Nephrology-team-performed percutaneous PD catheter insertion using a combined ultrasound and fluoroscopy- guided technique is safe, feasible, and associated with acceptable success and complication rates. Technical outcomes improved as the program matured, although this temporal change cannot be attributed solely to an individual operator learning curve. Urgent-start PD within 14 days is feasible but requires careful patient selection and management to minimize leakage risk. This approach can expand PD access, reduce reliance on surgical services, and support the growth of home-based dialysis programs in regional hospitals.

Authors contributions:

KSA: Conceptualization, supervision; HME: Writing – original draft, writing – review and editing; SSA: Investigation, data curation; AAA: Methodology, formal analysis; KSA-R: Writing – original draft, writing – review and editing; SAA-B: Methodology, formal analysis.

Ethical approval:

The research/study was approved by the Institutional Review Board at Research and Ethical Review and Approval Committee, Nizwa Hospital, Directorate General of Health Services (DGHS), Al Dakhliyah Governorate, Ministry of Health, Sultanate of Oman, number DGHS/R&S/PROPOSAL_APPROVED/2024, dated 25th July, 2024.

Declaration of patient consent:

Patient’s consent is not required as the patient’s identity is not disclosed or compromised.

Conflicts of interest:

There are no conflicts of interest.

Use of artificial intelligence (AI)-assisted technology for manuscript preparation:

The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript and no images were manipulated using AI.

Financial support and sponsorship: Nil.

References

  1. , , , , , , et al. Rate of decline of residual kidney function before and after the start of peritoneal dialysis. Perit Dial Int. 2016;36:334-9.
    [CrossRef] [PubMed] [Google Scholar]
  2. , , , , , , et al. Standardized outcomes in nephrology-peritoneal dialysis (SONG-PD): Study protocol for establishing a core outcome set in PD. Perit Dial Int. 2017;37:639-47.
    [CrossRef] [PubMed] [Google Scholar]
  3. , , . Is It time to give peritoneal dialysis its due place in managing acute kidney injury: Lessons learnt from COVID-19 pandemic. Blood Purif. 2024;53:71-9.
    [CrossRef] [PubMed] [Google Scholar]
  4. , , , , , , et al. Creating and maintaining optimal peritoneal dialysis access in the adult patient: 2019 update. Perit Dial Int. 2019;39:414-36.
    [CrossRef] [PubMed] [Google Scholar]
  5. , , , , . Comparison of outcomes between surgically placed and percutaneously placed peritoneal dialysis catheters: A retrospective study. Indian J Nephrol. 2016;26:268-74.
    [CrossRef] [PubMed] [Google Scholar]
  6. , , , , . A comparative analysis of percutaneous and open surgical techniques for peritoneal catheter placement. Perit Dial Int. 2012;32:628-35.
    [CrossRef] [PubMed] [Google Scholar]
  7. , , , , , , et al. Comparison of peritoneal catheter insertion techniques: A single-center experience comparing percutaneous and laparoscopic approaches: Catheter insertion and peritoneal dialysis. J Eur Intern Med Prof. 2023;1:144-9.
    [Google Scholar]
  8. , , , , , , et al. Comparative outcomes of image-guided percutaneous catheterization versus direct visualization catheterization for peritoneal dialysis: A meta-analysis. PLoS One. 2025;20:e0325600.
    [CrossRef] [PubMed] [Google Scholar]
  9. , , , , , , et al. ISPD catheter-related infection recommendations: 2017 update. Perit Dial Int. 2017;37:141-54.
    [CrossRef] [PubMed] [Google Scholar]
  10. , , , , , , et al. ISPD peritonitis recommendations: 2016 update on prevention and treatment. Perit Dial Int. 2016;36:481-508.
    [CrossRef] [PubMed] [Google Scholar]
  11. , , . Dialysate leaks in peritoneal dialysis. Semin Dial. 2001;14:50-4.
    [CrossRef] [PubMed] [Google Scholar]
  12. , , , , , . Laparoscopic-assisted placement of peritoneal dialysis catheters: Implantation technique and results. J Laparoendosc Adv Surg Tech A. 2007;17:596-9.
    [CrossRef] [PubMed] [Google Scholar]
  13. , , , . Prospective randomized study for comparison of open surgery with laparoscopic-assisted placement of Tenckhoff peritoneal dialysis catheter-a single center experience and literature review. J Surg Res. 2010;159:489-96.
    [CrossRef] [PubMed] [Google Scholar]
  14. , , , , . Comparative study of outcomes following laparoscopic versus open peritoneal dialysis catheter insertion at a tertiary care centre. J Urol Surg. 2021;8:40-5.
    [CrossRef] [Google Scholar]
  15. , , , , , , et al. Percutaneous versus surgical insertion of peritoneal dialysis catheters: A systematic review and meta-analysis. Can J Kidney Health Dis. 2021;8:20543581211052731.
    [CrossRef] [PubMed] [Google Scholar]
  16. , , . Technical survival of CAPD catheters: Comparison between percutaneous and conventional surgical placement techniques. Nephrol Dial Transplant. 2001;16:1893-9.
    [CrossRef] [PubMed] [Google Scholar]
  17. , , , , , , et al. Association between different peritoneal dialysis catheter placement methods and short-term postoperative complications. BMC Nephrol. 2021;22:151.
    [CrossRef] [PubMed] [Google Scholar]
  18. . Who should place peritoneal dialysis catheters? Perit Dial Int. 2010;30:142-50.
    [CrossRef] [PubMed] [Google Scholar]
  19. , , , , . Immediate initiation of CAPD following percutaneous catheter placement without break-in procedure. Perit Dial Int. 2007;27:179-83.
    [CrossRef] [Google Scholar]
  20. , , . Unplanned start on peritoneal dialysis right after PD catheter implantation for older people with end-stage renal disease. Perit Dial Int. 2015;35:622-4.
    [CrossRef] [PubMed] [Google Scholar]
Show Sections